407. Merlin IV NG Controller Retrofit Kit Installation

SUBJECT: Merlin IV NG Controller Retrofit Kit Installation REVISION: 01 MODELS: All Merlin IV models prior to serial number 201716GA00001 PURPOSE: This bulletin describes the procedure for installing the new Merlin IV NG controller in place of the smaller, older-style Merlin IV controller. Download PDF: Service Bulletin 407 … [Read more...]

189. 20 oz Propel Fitness Sport Cap bottle

Product name: 20 oz Propel Fitness Sport Cap bottle Bottler / company: The Gatorade Co. Volume: 20 oz / 591 mL Package type: PETE Height: 9.24 in / 234.8 mm Diameter: 2.82 in / 71.7 mm Weight: 1.35 lbs / 0.61 kg Country of origin: USA Venders: Merlin IV, TDV, RVV 500 Download PDF: PVS 189 … [Read more...]

191. 20 oz Faygo bottle

Product name: 20 oz Faygo bottle Bottler / company: Faygo Beverages, Inc. Volume: 20 oz / 591 mL Package type: PETE (returnable) Height: 7.89 in / 200.3 mm Diameter: 2.90 in / 73.6 mm Weight: 1.40 lbs / 0.64 kg Country of origin: USA Venders: Merlin IV Download PDF: PVS 191 … [Read more...]

399. Reinforced T-handle Lock Cylinder Cover Kit Installation

SUBJECT: Reinforced T-handle Lock Cylinder Cover Kit Installation REVISION: 00 MODELS: All ADA venders and GIII Marketing PURPOSE OF THIS BULLETIN: The reinforced T-handle lock cylinder cover blocks off the T-handle to prevent access to the latch cylinder by vandals. Download PDF: Service Bulletin 399 … [Read more...]

398. 20 oz Anti-bridging Kit for Merlin IV

SUBJECT: 20 oz Anti-bridging Kit for Merlin IV REVISION: 00 MODELS: 72" Merlin IV (models 650 and 542) PURPOSE OF THIS BULLETIN: In certain vintages of Merlin IV venders, bridging may occur with some 20 ounce bottles. In the event this occurs, this anti-bridging kit should alleviate the issue. Download PDF: Service Bulletin 398 … [Read more...]

Custom Space-to-Sales – Merlin IV

Push the mode button on the control board. Push #1 selection until “PASS,” hit the #3 selection, then input pass code (4231).  Note:  Revision 67100-6 and higher will not include PASS. Push #1 selection until “STOS,” then push #3 selection to enter in. Push #1 selection until “OPT 0,” and enter in with the #3 selection.  The LED will scroll “SL 1” through “SL10,” then “NONE.” Hold the #3 … [Read more...]

Setting Price – Merlin IV

Push the mode button on the control board. Push #1 selection until “PASS,” hit the #3 selection, then input pass code (4231).  Note:  Revision 67100-6 and higher will not include PASS. Push the #1 selection until “PRIC,” then hit the #3 selection to enter. You will see “P 1.”  This stands for price 1.  Prices are set by selection number. Push the #1 selection to scroll through selections 1 … [Read more...]

Setting Depth – Merlin IV

Push the mode button on the control board. Push #1 selection until “PASS,” hit the #3 selection, then input pass code (4231). Note: Revision 67100-6 and higher will not include PASS. Push the #1 selection until “SDEP,” then enter in with the #3 selection. You will see “S1” (selection 1), followed by a 1, 2, or 3 (depth setting). You can scroll though selections 1-12 or “ALL” with #1 … [Read more...]

80. Installation of Changer Jacket

SUBJECT: Installation of Changer Jacket REVISION: 03 MODELS: All venders PURPOSE: This bulletin explains the procedure for installing a rubber jacket around the top section of the changer. Download PDF: Service Bulletin 80 … [Read more...]

18. Compressor Jumper Test Kit

SUBJECT: Compressor Jumper Test Kit REVISION: 04 MODELS: All venders PURPOSE: The purpose of the compressor jumper test kit is to provide a simple on-site check for the cause of failure when the compressor will not operate and vender has correct power. Download PDF: Service Bulletin 18 … [Read more...]