400. Health Sensor Field Test

SUBJECT: Health Sensor Field Test (Full-cycle Sensor-controlled Test) REVISION: 00 MODELS: All Coolers and Freezers with Health Safety Controllers TOOLS REQUIRED: Phillips screwdriver ESTIMATED TEST PROCEDURE TIME: About 45 minutes PURPOSE: The procedure below can be used to determine whether or not the equipment's Health Safety Controller functions correctly. Download PDF: Service … [Read more...]

401. Coin Deflector Kit Installation

SUBJECT: Coin Deflector Kit Installation REVISION: 00 MODELS: GIII venders with Center Door Changer PURPOSE OF THIS BULLETIN: This bulletin describes the procedure for installing the coin deflector kit in GIII venders with Center Door Changers. Download PDF: Service Bulletin 401 … [Read more...]

77. Cooler / Freezer Door Gasket Reforming Procedure

Subject: Cooler / Freezer Door Gasket Reforming Procedure Revision: 02 Models: All Cooler and Freezer models Tools required: Heat gun Estimated time: <10 minutes Information: When a replacement door assembly is received for a Cooler or Freezer, the gasket may need to be reformed, if there are gaps between the door and the cabinet. This procedure describes how to reform the … [Read more...]

191. 20 oz Faygo bottle

Product name: 20 oz Faygo bottle Bottler / company: Faygo Beverages, Inc. Volume: 20 oz / 591 mL Package type: PETE (returnable) Height: 7.89 in / 200.3 mm Diameter: 2.90 in / 73.6 mm Weight: 1.40 lbs / 0.64 kg Country of origin: USA Venders: Merlin IV Download PDF: PVS 191 … [Read more...]

399. Reinforced T-handle Lock Cylinder Cover Kit Installation

SUBJECT: Reinforced T-handle Lock Cylinder Cover Kit Installation REVISION: 00 MODELS: All ADA venders and GIII Marketing PURPOSE OF THIS BULLETIN: The reinforced T-handle lock cylinder cover blocks off the T-handle to prevent access to the latch cylinder by vandals. Download PDF: Service Bulletin 399 … [Read more...]

398. 20 oz Anti-bridging Kit for Merlin IV

SUBJECT: 20 oz Anti-bridging Kit for Merlin IV REVISION: 00 MODELS: 72" Merlin IV (models 650 and 542) PURPOSE OF THIS BULLETIN: In certain vintages of Merlin IV venders, bridging may occur with some 20 ounce bottles. In the event this occurs, this anti-bridging kit should alleviate the issue. Download PDF: Service Bulletin 398 … [Read more...]

397. Optimized Placement of Bimetal Switch

SUBJECT: Optimized Placement of Bimetal Switch REVISION: 02 MODELS: Freezer PURPOSE OF THIS BULLETIN: On Royal Vendors Freezers with serial numbers 201518RA00054 and before, the bimetal switch in the refrigeration assembly was placed on the 1/4" line going into the expansion valve, which may not allow the cabinet to pull down to the correct temperature. This bulletin explains the procedure … [Read more...]

76. GIII Vend Motor Troubleshooting Procedure

Subject: GIII Vend Motor Troubleshooting Procedure Revision: 00 Models: All GIII venders Tools required: Voltmeter Estimated time: N/A Information: This document describes the procedure for troubleshooting problems related to the vend motor on GIII venders. Download PDF: Helpful Hint 76 … [Read more...]

75. Coin Changer Fit and Coin Chute Adjustment in GIII CDC

Subject: Coin Changer Fit and Coin Chute Adjustment in GIII CDC Revision: 00 Models: GIII with Center Door Changer Tools required: N/A Estimated time: N/A Information: This document describes the procedure for properly fitting the changer in GIII CDC venders, as well as proper coin chute adjustment. Download PDF: Helpful Hint 75 … [Read more...]

396. Enabling the Battery on the Health Timer Freezer Controller

SUBJECT: Enabling the Battery on the Health Timer Freezer Controller REVISION: 00 MODELS: Health Safety Freezer REASON FOR BULLETIN: The Health Safety Freezer Controller's backup battery is disabled when not installed in the Freezer to preserve its shelf life. Failure to enable the battery will cause the door lock mechanism to stay in the locked position in the event the Freezer loses … [Read more...]